Description
Specification
In-place installation (M10 to M24) and pre-positioned installation (M8 to M24)
High loads, minimum spacing and edge distances
The bonded anchor is suitable for cracked concrete (concrete tensile zone) and non-cracked concrete (concrete compressive zone)
The drill holes can be created using a hammer drill (W-VIZ M8 to M24), vacuum drill (W-VIZ M10 to M24) or diamond drill process (W-VIZ M10 to M24)
Hardened chemical injection mortar largely seals off the drill hole
Attachment with low expansion pressure allows minimum spacing and edge distances
Geometry of anchor rod allows safe follow-up expansion capability
Mechanical drill hole cleaning: Easy handling, very good drill hole cleaning, high loads
Safe installation if the specified torque is applied when installing the anchor
Force-controlled/torque-controlled expansion anchors made of stainless steel in sizes M8, M10, M12, M16, M20 and M24
The load is transferred via the mechanical interlocking of individual cones in the injection mortar and also via a combination of retention and frictional forces in the base material (concrete) | In-place installation (M10 to M24) and pre-positioned installation (M8 to M24) | High loads, minimum spacing and edge distances | The bonded anchor is suitable for cracked concrete (concrete tensile zone) and non-cracked concrete (concrete compressive zone) | The drill holes can be created using a hammer drill (W-VIZ M8 to M24), vacuum drill (W-VIZ M10 to M24) or diamond drill process (W-VIZ M10 to M24) | Hardened chemical injection mortar largely seals off the drill hole | Attachment with low expansion pressure allows minimum spacing and edge distances | Geometry of anchor rod allows safe follow-up expansion capability | Mechanical drill hole cleaning: Easy handling, very good drill hole cleaning, high loads | Safe installation if the specified torque is applied when installing the anchor | Force-controlled/torque-controlled expansion anchors made of stainless steel in sizes M8, M10, M12, M16, M20 and M24 | The load is transferred via the mechanical interlocking of individual cones in the injection mortar and also via a combination of retention and frictional forces in the base material (concrete) | Notice | Suitable injectable mortar: WIT-VIZ, WIT-VIZ Express | European technical assessment ETA-04/0095 for fixing point option 1, cracked and non-cracked concrete, seismic performance category C1 and C2
Fire resistance: F30, F60, F90 and F120 | European technical assessment ETA-04/0095 for fixing point option 1, cracked and non-cracked concrete, seismic performance category C1 and C2 | Fire resistance: F30, F60, F90 and F120
Application
Application area | The anchor has a European technical assessment for use in reinforced or unreinforced normal weight concrete with a concrete compressive strength of min. C20/25 and max. C50/60 in accordance with EN 206-1:2000-12
Anchorage with European technical assessment in cracked concrete (concrete tensile zone) and non-cracked concrete (concrete compressive zone)
Static (e.g. dead load, equipment, storage materials) or quasi-static (e.g. staircase railings) actions: M8 to M24
Seismic effects, earthquakes (category C1 + C2): M10 to M24
Anchor size M8 to M24: Installation in dry or wet concrete
Anchor sizes M12 to M24: installation in water-filled drill holes (exception: W-VIZ-A 75 M12 – installation in water-filled drill holes not permitted)
For use in concrete < C20/25 and pressure-resistant natural stone (without approval)
W-VIZ/A4 (stainless steel A4) can be used in dry indoor areas, outdoors (including in industrial atmospheres and coastal areas) or in wet rooms
Suitable for fastening metal structures, metal profiles, brackets, base plates, supports, railings, wooden structures, beams etc. | The anchor has a European technical assessment for use in reinforced or unreinforced normal weight concrete with a concrete compressive strength of min. C20/25 and max. C50/60 in accordance with EN 206-1:2000-12 | Anchorage with European technical assessment in cracked concrete (concrete tensile zone) and non-cracked concrete (concrete compressive zone) | Static (e.g. dead load, equipment, storage materials) or quasi-static (e.g. staircase railings) actions: M8 to M24 | Seismic effects, earthquakes (category C1 + C2): M10 to M24 | Anchor size M8 to M24: Installation in dry or wet concrete | Anchor sizes M12 to M24: installation in water-filled drill holes (exception: W-VIZ-A 75 M12 - installation in water-filled drill holes not permitted) | For use in concrete < C20/25 and pressure-resistant natural stone (without approval) | W-VIZ/A4 (stainless steel A4) can be used in dry indoor areas, outdoors (including in industrial atmospheres and coastal areas) or in wet rooms | Suitable for fastening metal structures, metal profiles, brackets, base plates, supports, railings, wooden structures, beams etc. | Instructions | Clean the drill hole: 2x blow-out, 2x mechanical brush-out, 2x blow-out | If the drill hole is M20 or larger, blow out with pneumatic air using the appropriate pneumatic air nozzles
Tehnical Information
Type description: W-VIZ-A/A4 | Metric anchor diameter: M8 | Effective anchoring depth (h ef): 40 mm | Attachment height (t fix): 15 mm | Anchor length (l): 65 mm | Nominal drill-bit diameter (d 0): 10 mm | Drill hole depth (h 0): 42 mm | Required injection mortar: WIT-VM 100, WIT-Express, WIT-VIZ, WIT-VIZ express | Approval: ETA-04/0095 | Material: Stainless steel A4