Approved for high loads in concrete (individual fixing point), autoclaved aerated concrete and masonry | Virtually no movement of the anchor sleeve | Low screw-in torque of the plug screw
“Slight” spreading of the anchor | Low screw-in torque of the plug screw | “Slight” spreading of the anchor | Reliable post-spreading characteristics | Enabled by geometry of the SymCon plug screw | Increased load introduction | Screwing in the SymCon screw results in optimum compression of the plastic of the plug screw (almost no back-cut) | Low assembly workload | Wall plug body and special screw are pre-assembled | Saves an additional U washer and prevents contact corrosion | Multiple insertion depths | Concrete: 3 insertion depths (40, 50 and 70 mm)
Masonry: 2 insertion depths (50 and 70 mm) | Concrete: 3 insertion depths (40, 50 and 70 mm) | Masonry: 2 insertion depths (50 and 70 mm) | Proof of Performance | European Technical Approval ETA-11/0309 | Notice | When anchoring in solid brick and solid sand-lime brick, we recommend performing pull-out tests due to differences in brick manufacturing | Application area | Metal substructures | Metal substructures | Metal substructures | Create the drill hole
Clean the drill hole
Set anchor and screw
Screw in the screw
Screw in screw until flush | Create the drill hole | Create the drill hole | Clean the drill hole | Clean the drill hole | Set anchor and screw | Set anchor and screw | Set anchor and screw | Screw in the screw | Screw in the screw | Screw in the screw | Screw in screw until flush | Screw in screw until flush | Screw in screw until flush | Create the drill hole
Clean the drill hole
Set anchor and screw
Screw in the screw
Screw in screw until flush | Create the drill hole | Create the drill hole | Clean the drill hole | Clean the drill hole | Set anchor and screw | Set anchor and screw | Screw in the screw | Screw in the screw | Screw in screw until flush | Screw in screw until flush | European Technical Approval ETA-11/0309
Application
Application area | Multiple attachment of non-load-bearing systems with approval | E.g. façade, ceiling, or roof substructures (made from wood or steel), pipelines, cable ducts, wooden beams, wooden slats, brackets, wall cabinets, shelves, etc. | Anchoring bases | Standard concrete
Aerated concrete
Cladding
Hollow-core prestressed concrete ceilings
Masonry walls (solid brick, solid sand-lime brick, vertically perforated brick, perforated sand-lime brick, hollow lightweight concrete blocks, solid bricks and blocks made of lightweight concrete, concrete bricks) | Standard concrete | Aerated concrete | Cladding | Hollow-core prestressed concrete ceilings | Masonry walls (solid brick, solid sand-lime brick, vertically perforated brick, perforated sand-lime brick, hollow lightweight concrete blocks, solid bricks and blocks made of lightweight concrete, concrete bricks)
Tehnical Information
Anchor diameter: 10 mm | Anchor length (l): 50 mm | Nominal drill-bit diameter (d 0): 10 mm | Through-hole in the component to be connected (d f): 10.5 mm | Attachment height (t fix 1): 10 mm | Material of screw: Steel | Internal drive: AW40 | Surface of the screw: Zinc plated | Head type: Hexagon washer head | Approval: ETA-11/0309 | Type description: W-UR F 10 SymCon, hexagonal bolt | 50°C2)/80°C3): 2,14