Description
Specification
Heavy-duty anchor for high loads in cracked and non-cracked concrete, ideal for flush-mounted fixtures, such as railings or handrails. Stainless steel A4 | High load-bearing capacities
Time-saving push-through installation
Immediate load-bearing capacity – no waiting
Torque-controlled expanding A4 stainless steel anchor
Countersunk head design for an elegant appearance (e.g. railings) | High load-bearing capacities | Time-saving push-through installation | Immediate load-bearing capacity – no waiting | Torque-controlled expanding A4 stainless steel anchor | Countersunk head design for an elegant appearance (e.g. railings) | Proof of Performance | ETA-02/0031 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2
Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 1363-1:1999-10 (uniform temperature-time curve)
Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-02/0031) | ETA-02/0031 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2 | Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 1363-1:1999-10 (uniform temperature-time curve) | Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-02/0031) | Application area | Railings
Handrails | Railings | Railings | Railings | Handrails | Handrails | Handrails | Create the drill hole
Clean the drill hole | Create the drill hole | Create the drill hole | Create the drill hole | Clean the drill hole | Clean the drill hole | Clean the drill hole | ETA-02/0031 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2
Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 1363-1:1999-10 (uniform temperature-time curve)
Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-02/0031) | ETA-02/0031 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2 | Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 1363-1:1999-10 (uniform temperature-time curve) | Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-02/0031)
Application
Application area | Individual attachment with approval | Normal concrete C20/25 to C50/60 (cracked and non-cracked concrete, seismic performance category C1 and C2 for sizes M8–M12) | e.g. metal structures, metal profiles, brackets, base plates, supports, cable conduits, pipes, railings, machines etc. | Individual attachment without approval | Can be used in concrete < C20/25 and compression-proof natural stone | Approved for use in dry indoor areas and also outdoors (including industrial atmospheres and coastal areas) or in damp rooms, provided that no particularly aggressive conditions are present
Tehnical Information
Material: Stainless steel A4 | Metric anchor diameter: M12 | Anchor length (l): 135 mm | Max. attachment height (t fix): 40 mm | Countersink diameter: 29.5 mm | Countersinking depth: 6.7 m | Nominal drill-bit diameter (d 0): 18 mm | Drill hole depth (h 1): 105 mm | Effective anchoring depth (h ef): 80 mm | Approval: ETA-02/0031