Wurth DROP IN ANCHOR W ED S ANC W ED S A2K M6 (100 pack)

£45.63

Art.-no. 090401006 / EAN 4038898600886

SKU: 223c47e0e135 Category:

Description

Specification
Female thread anchor with metric thread for economical anchoring in concrete, zinc-plated steel | Small drill hole depth

High load-bearing capacities

Visual setting check and hand protection when installing with the marking/expander tool

Mechanical setting tool makes installation quicker and easier

Immediate load-bearing capacity – no waiting

Attached part can easily be removed at any time

The attached part can be anchored with a fastening screw or a threaded rod

No installation torque required

The stop bit used with the attachable expander tool makes it quicker and easier to install. The matching drill holes make the installation even more secure. | Small drill hole depth | High load-bearing capacities | Visual setting check and hand protection when installing with the marking/expander tool | Mechanical setting tool makes installation quicker and easier | Immediate load-bearing capacity – no waiting | Attached part can easily be removed at any time | The attached part can be anchored with a fastening screw or a threaded rod | No installation torque required | The stop bit used with the attachable expander tool makes it quicker and easier to install. The matching drill holes make the installation even more secure. | Proof of Performance | ETA-02/0044 for individual fixing point, option 7, uncracked concrete

ETA-05/0120 for anchors in a redundant non-structural system, uncracked and cracked concrete, M6-M16

Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (UTTC – uniform temperature time curve)

Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-05/0120) | ETA-02/0044 for individual fixing point, option 7, uncracked concrete | ETA-05/0120 for anchors in a redundant non-structural system, uncracked and cracked concrete, M6-M16 | Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (UTTC – uniform temperature time curve) | Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-05/0120) | Notice | Drive-in anchor W-ED/A4 see [13.2] | Drive-in anchor W-ED, M12 (for core drills), and W-ED, DW15, see [13.3] | Application area | Suspended ceilings | Suspended ceilings | Suspended ceilings | Drill the hole
Clean the drill hole
Knock in anchor until flush
Anchor with expander tool
Fit component, apply torque | Drill the hole | Drill the hole | Drill the hole | Clean the drill hole | Clean the drill hole | Clean the drill hole | Knock in anchor until flush | Knock in anchor until flush | Knock in anchor until flush | Anchor with expander tool | Anchor with expander tool | Anchor with expander tool | Fit component, apply torque | Fit component, apply torque | Fit component, apply torque | ETA-02/0044 for individual fixing point, option 7, uncracked concrete

ETA-05/0120 for anchors in a redundant non-structural system, uncracked and cracked concrete, M6-M16

Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (UTTC – uniform temperature time curve)

Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-05/0120) | ETA-02/0044 for individual fixing point, option 7, uncracked concrete | ETA-05/0120 for anchors in a redundant non-structural system, uncracked and cracked concrete, M6-M16 | Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (UTTC – uniform temperature time curve) | Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-05/0120)
Application
Application area | Individual fixing point: Normal weight concrete C20/25 to C50/60 (uncracked concrete) | Anchors in a redundant non-structural system: Anchorage of non-load-bearing systems (M6-M16, cracked and uncracked concrete) | E.g. threaded rods, metal structures, metal profiles, lattices, cable conduits, pipes, mounting rails etc. | For use in concrete < C20/25 and pressure-resistant natural stone (without approval) | May only be used in dry indoor conditions Tehnical Information
Anchor diameter: 6 mm | Anchor length (L H): 30 mm | Min./max. required screw-in depth: 7-13 mm | Material: Steel | Surface: Zinc plated | Nominal drill-bit diameter (d 0): 8 mm | Drill hole depth (h 0): 30 mm | Effective anchoring depth (h ef): 30 mm | Torque during anchoring (T inst): 4 Nm | Through-hole in the component to be connected (d f): 7 mm | Approval: ETA-02/0044, ETA-05/0120