Description
Specification
Heavy-duty anchor for high loads in cracked and non-cracked concrete, clean finish on the attached part. Zinc-plated steel | High load-bearing capacities
Time-saving push-through installation
Immediate load-bearing capacity — no waiting
Torque-controlled expanding galvanised steel anchor | High load-bearing capacities | Time-saving push-through installation | Immediate load-bearing capacity — no waiting | Torque-controlled expanding galvanised steel anchor | Proof of Performance | ETA-02/0031 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2
Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 1363-1:1999-10 (uniform temperature-time curve)
Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-02/0031) | ETA-02/0031 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2 | Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 1363-1:1999-10 (uniform temperature-time curve) | Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-02/0031) | Application area | Create the drill hole
Clean the drill hole | Create the drill hole | Create the drill hole | Create the drill hole | Clean the drill hole | Clean the drill hole | Clean the drill hole | ETA-02/0031 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2
Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 1363-1:1999-10 (uniform temperature-time curve)
Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-02/0031) | ETA-02/0031 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2 | Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 1363-1:1999-10 (uniform temperature-time curve) | Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-02/0031)
Application
Application area | Normal concrete C20/25 to C50/60 (cracked and non-cracked concrete, seismic performance category C1 and C2 for sizes M8–M20) | e.g. metal structures, metal profiles, brackets, base plates, supports, cable conduits, pipes, railings, machines etc. | Individual attachment without approval | Can be used in concrete < C20/25 and compression-proof natural stone | W-HAZ/S approved only for use in dry indoor room conditions
Tehnical Information
Anchor length (l): 100 mm | Material: Steel | Surface: Zinc plated