Wurth HIGH PERFORMANCE ANCHOR WITH STUD BOLTS W HAZ B A4 ANC W HAZ B A4 0 M8X80 (50 pack)

£660.79

Art.-no. 05932612101 / EAN 4052703211685

SKU: 16a3218077c1 Category:

Description

Specification
Heavy-duty anchor for high loads in cracked and non-cracked concrete. Stainless steel A4 | High load-bearing capacities

Time-saving push-through installation

Immediate load-bearing capacity – no waiting

Torque-controlled expanding A4 stainless steel anchor | High load-bearing capacities | Time-saving push-through installation | Immediate load-bearing capacity – no waiting | Torque-controlled expanding A4 stainless steel anchor | Proof of Performance | ETA-02/0031 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2

Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 1363-1:1999-10 (uniform temperature-time curve)

Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-02/0031) | ETA-02/0031 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2 | Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 1363-1:1999-10 (uniform temperature-time curve) | Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-02/0031) | Application area | Create the drill hole
Clean the drill hole | Create the drill hole | Create the drill hole | Create the drill hole | Clean the drill hole | Clean the drill hole | Clean the drill hole | ETA-02/0031 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2

Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 1363-1:1999-10 (uniform temperature-time curve)

Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-02/0031) | ETA-02/0031 for individual attachment, option 1, cracked and non-cracked concrete, seismic performance category C1 and C2 | Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 1363-1:1999-10 (uniform temperature-time curve) | Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-02/0031)
Application
Application area | Individual fixing point with approval | Normal weight concrete C20/25 to C50/60 (cracked and uncracked concrete, seismic performance category C1 and C2 for sizes M8-M16)

Examples include metal structures, metal profiles, brackets, base plates, supports, cable conduits, pipes, railings, machinery etc. | Normal weight concrete C20/25 to C50/60 (cracked and uncracked concrete, seismic performance category C1 and C2 for sizes M8-M16) | Examples include metal structures, metal profiles, brackets, base plates, supports, cable conduits, pipes, railings, machinery etc. | Individual fixing point without approval | For use in concrete < C20/25 and pressure-resistant natural stone | Can be used in dry indoor areas, outdoors (including in industrial atmospheres and close to the sea) or in wet rooms, provided that no particularly aggressive conditions are present Tehnical Information
Metric anchor diameter: M8 | Anchor length (l): 80 mm | Max. attachment height (t fix): 0 mm | Width across flats: 13 mm | Nominal drill-bit diameter (d 0): 12 mm | Drill hole depth (h 1): 80 mm | Effective anchoring depth (h ef): 60 mm | Material: Stainless steel A4