Description
Specification
Fixanchors for standard applications in uncracked concrete and anchors in a redundant non-structural system in cracked concrete (size M6). A4 stainless steel | Very flexible application thanks to three effective anchorage depths
Small spacings and edge distances
Time-saving push-through installation | Very flexible application thanks to three effective anchorage depths | Small spacings and edge distances | Time-saving push-through installation | Proof of Performance | European Technical Assessment ETA-02/0001 for individual fixing point, option 7, uncracked concrete: Static or quasi-static action (M6-M20)
European Technical Assessment ETA-06/0162 for anchors in a redundant non-structural system in non-load-bearing systems, cracked and uncracked concrete, size M6
Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (UTTC – uniform temperature time curve)
Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-06/0162, size M6 only) | European Technical Assessment ETA-02/0001 for individual fixing point, option 7, uncracked concrete: Static or quasi-static action (M6-M20) | European Technical Assessment ETA-06/0162 for anchors in a redundant non-structural system in non-load-bearing systems, cracked and uncracked concrete, size M6 | Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (UTTC – uniform temperature time curve) | Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-06/0162, size M6 only) | Application area | Heavy steel structures
Fence systems
Post support bracket | Heavy steel structures | Heavy steel structures | Fence systems | Fence systems | Post support bracket | Post support bracket | Drill the hole
Clean the drill hole
Knock in anchor with mason’s mallet or machine setting tool
Apply torque | Drill the hole | Drill the hole | Clean the drill hole | Clean the drill hole | Knock in anchor with mason’s mallet or machine setting tool | Knock in anchor with mason’s mallet or machine setting tool | Apply torque | Apply torque | European Technical Assessment ETA-02/0001 for individual fixing point, option 7, uncracked concrete: Static or quasi-static action (M6-M20)
European Technical Assessment ETA-06/0162 for anchors in a redundant non-structural system in non-load-bearing systems, cracked and uncracked concrete, size M6
Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (UTTC – uniform temperature time curve)
Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-06/0162, size M6 only) | European Technical Assessment ETA-02/0001 for individual fixing point, option 7, uncracked concrete: Static or quasi-static action (M6-M20) | European Technical Assessment ETA-06/0162 for anchors in a redundant non-structural system in non-load-bearing systems, cracked and uncracked concrete, size M6 | Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (UTTC – uniform temperature time curve) | Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-06/0162, size M6 only)
Application
Application area | Individual fixing point or anchors in a redundant non-structural system with European Technical Approval in normal weight concrete C20/25 to C50/60 (uncracked concrete only)
Anchors in a redundant non-structural system in non-load-bearing systems in concrete (size M6, cracked and uncracked concrete)
For use in concrete < C20/25 and pressure-resistant natural stone (without approval/assessment)
Fastenings under exposure to fire (size M6 only)
Suitable for anchoring medium to heavy loads in concrete: Mounting of e.g. metal structures, metal profiles, brackets, base plates, cable conduits, pipes, wooden structures, beams, purlins, fences etc.
W-FA/A4 (A4 stainless steel) is suitable for use in dry indoor areas or wet rooms and for use outdoors (including in industrial atmospheres and close to the sea), provided that no particularly aggressive conditions are present | Individual fixing point or anchors in a redundant non-structural system with European Technical Approval in normal weight concrete C20/25 to C50/60 (uncracked concrete only) | Anchors in a redundant non-structural system in non-load-bearing systems in concrete (size M6, cracked and uncracked concrete) | For use in concrete < C20/25 and pressure-resistant natural stone (without approval/assessment) | Fastenings under exposure to fire (size M6 only) | Suitable for anchoring medium to heavy loads in concrete: Mounting of e.g. metal structures, metal profiles, brackets, base plates, cable conduits, pipes, wooden structures, beams, purlins, fences etc. | W-FA/A4 (A4 stainless steel) is suitable for use in dry indoor areas or wet rooms and for use outdoors (including in industrial atmospheres and close to the sea), provided that no particularly aggressive conditions are present
Tehnical Information
Metric anchor diameter: M12 | Anchor length (l): 200 mm | Material: Stainless steel A4 | Attachment height (t fix): 105 mm | Max. attachment height reduced (t fix, red): 120 mm | Attachment height (t fix 2): 120 mm | Drill hole depth (h 1): 90 mm | Drill hole depth reduced (h 1, red): 75 mm | Drill hole depth (h 1.2): 75 mm | Effective anchoring depth (h ef): 65 mm | Effective anchoring depth reduced (h ef, red): 50 mm | Effective anchoring depth (h ef 2): 50 mm | Embedding depth (h nom): 81 mm | Embedding depth (h nom,red): 66 mm | Width across flats: 19 mm | Nominal drill-bit diameter (d 0): 12 mm | Through-hole in the component to be connected (d f): 14 mm | Thread length (L th): 80 mm | Approval: ETA-02/0001